Key Features
Contains a heating element which is heated to 100°C (212°F) on the default setting for the destruction of human tissue. The probe tip should only be applied to tissue which is intended to be ablated. The probe heats quickly (5-8 seconds) and can be autoclaved for sterilization.
Specifications
- Ambient Temperature: 10 to 40 degrees Celsius
- Relative Humidity: 0% to 80% non-condensing
Transport and Storage
- Ambient Temperature: -40 to 70 degrees Celsius
- Relative Humidity: 0% to 80% non-condensing
General Information
- Type B Applied Parts
- IP21 Rating: Solid particle protection: Level 2 (>12.5mm), Liquid ingress protection: Level 1 (dripping water)
Standard Accessories
Optional Accessories & Add-ons
Product Documents, Manuals & Brochures
Manual
Instruction Pamphlet
Regulatory Certificates
Battery Data Sheet
FDA Certificate
ISO-13845
CE Certificate
Videos
FAQ
How do I clean the Probe?
Place the silicon cap firmly over the connector end. Clean any debris off the probe with mild detergent and water using a soft cloth or soft brush, then rinse in clean water.
Place the probes upright in a cup (approximately 5- 6” deep) of ~2.5% gluteraldeyde (Cydex) for 20-60 minutes (some sites use a 0.5% Chlorine solution-Chlorox).
This allows the connector end not to be immersed in solution which is not necessary as the connector end is not inserted into the patient nor contacts the patient and need not be sterilized.
Some users apply a heat cycle of the device to assure that the heated end has reached a sterilization temperature but this is unnecessary and regulatory agencies have not approved this procedure for sterilization. It certainly does sterilize the tip as all viral proteins are denatured above 60’C.
Rinse the probe end (not the connector end with the silicone cap) with clean, non-contaminated water, thoroughly dry the probe in air.
Wrap in clean material to keep it from being contaminated before next use.
The handle can, if needed, be wiped clean with a cloth dampened with a small amount of alcohol.
Box Contents
- 1x Thermocoagulator 19mm Nipple Probe for HTU-110
Warranty
Liger’s obligation under this warranty is limited to the repair or replacement, as its sole option, of any product, or part thereof, which has been returned to it or its Distributor within the applicable time period shown below, after delivery of the product to the original purchaser, and which examination discloses, to Liger’s satisfaction, that the product is indeed, defective.
This warranty does not apply to any product, or part thereof, which has been repaired or altered outside Liger’s factory in a way so as, in Liger’s judgment, to affect its stability or reliability, or which has been subjected to misuse, neglect, or accident.
This warranty is in lieu of all other warranties, express or implied, including without limitation, the warranties of merchantability and fitness for a particular purpose, and of all other obligations or liabilities on the part of Liger.
Liger neither assumes nor authorizes any other person to assume for it any other liability in connection with the sale or use of any of Liger’s products.
Notwithstanding any other provision herein or in any other document or communication, Liger’s liability with respect to this agreement and products sold hereunder shall be limited to the aggregate purchase price for the goods sold by Liger to the customer.
Liger disclaims any liability hereunder or elsewhere in connection with the sale of this product, for indirect or consequential damages.
This warranty and the rights and obligations hereunder shall be construed under and governed by the laws of the State of Utah, United States of America (USA). The sole forum for resolving disputes arising under or relating in any way to this warranty is the 3rd District Court of Utah, USA. Liger, its dealers, and representatives reserve the right to make changes in equipment built and/or sold by them at any time without incurring any obligation to make the same or similar changes on equipment previously built and/or sold by them.
Testimonials
Smyta Joshi, MD Hirabai Hospital Pune, India
Dr. Kofi Effah , Cervical Cancer Prevention and Training Centre, Catholic Hospital, Battor, Ghana
Beatrice Kabota, Nkhoma CCAP Hospital, Lilongwe Malawi